냉각 용량:
150톤
압축기 유형:
반 밀폐형 나사
증발기:
원통 다관형
콘덴서:
알루미늄 핀 동관 + 축 팬
냉장료:
R134a/R407C/R22
강조하다:

Sheet Extruder Air Cooled Screw Chiller

,

Industrial Air Cooled Screw Chiller

,

150HP Air Cooled Screw Chiller

지불과 운송 용어
최소 주문 수량
1
포장 세부 사항
접착판 케이스
배달 시간
30일
지불 조건
T/T, L/C
제품 설명

150HP Air Cooled Screw Compressor Chiller Industrial  chemical chiller 150Ton Air cooling machine for Sheet Extruder.

 

Using chillers to cool sheet extruders is one of the key applications in the plastics processing industry. Its stability and accuracy directly affect the quality of the sheet (such as thickness uniformity, surface gloss, crystallinity, etc.)
 

 

Model

Parameter

AGS-150ADH
Nominal cooling capacity TR 107.1
  kw 377
Input power kw 132.4
Max. Running current A 301.87
Power supply 3PH~380V/50HZ
Refrigerant Type R407C
  Type of control Expansion valve
Compressor Type Semi-hermetic screw
  Power 66.2kw*2
  Model /
  Start-up mode Y-△
  Capacity control 0-25-50-75-100
Evaporator Type Shell and tube
  Chilled fluid flow (m3/h) 64.8
  Inlet and outlet pipe diameter (inch) 5
Condenser Type Air cooled type finned copper tube
Fan Power(kw) 22.3
  Air flow (m3/h) 132000
Safety protection compressor over temperature, unit overload, high and low pressure, flow switch, phase sequence, phase-missing, anti-freezing
Dimension mm 6550*2150*2000
Net weight kg 4200
Running weight Kg 4430
 
 

Common problems and solutions for chiller condensers:
1. Condenser is dirty and clogged: The fins are covered with dust, oil, catkins, etc., resulting in poor heat dissipation, increased condensation pressure/temperature, and decreased refrigeration efficiency.
Treatment: Clean the condenser regularly (clean scale/biological algae for water-cooled type; clean fins for air-cooled type).

2. Insufficient cooling water flow/too high water temperature (water-cooled type): water pump failure, filter blockage, valve not fully opened, low cooling tower efficiency.
Treatment: Check the operation of the water pump, clean the filter, check the valve opening, and ensure that the cooling tower is working properly (fan, water distributor).

3. Condenser fan failure/insufficient air volume (air-cooled type): The fan motor is damaged, the belt is loose, the fan blades are deformed, the ambient temperature is too high or the ventilation is poor.
Treatment: Check the operating status of the fan, replace damaged parts, and improve the ventilation environment.

4. Condensation pressure is too high: In addition to heat dissipation problems, it may also be too much refrigerant or non-condensable gas (air) mixed into the system.
Treatment: Check the heat dissipation and have professionals check the refrigerant quantity and system vacuum degree if necessary.

 

 

The benefits of using air-cooled chillers:

  1. No cooling towers.
  2. Better environmental stability-no water wastage.
  3. Low maintenance costs.
  4. Easier to operate and control-tower freezing and tower bypass absent.
  5. Chemical costs avoided.
  6. Water costs avoided, especially in cities.

 

 

 

 

 

 

 


 

 

 

 

직접적으로 당신의 조사를 우리에게 보내세요

개인 정보 정책 중국 상등품 공업 용수 냉각장치 공급자. 저작권 (c) 2022-2025 Shenzhen Anges Machinery Co., Ltd . 무단 복제 금지.